Technical Bulletin |
|
|
4:1 Waterborne Acrylic Epoxy |
||
|
ALLPRO® Corporation |
AP4300 - 12260 |
| Description |
A two component, 4:1 mix ratio, high gloss
system that is a superior catalyzed coating for walls and other surfaces
combining the resistance properties of epoxy along with the color and
gloss retention of acrylics. |
| Prominent Features |
|
| Uses |
Use on wood, concrete, plaster, primed and previously painted metal. Ideal for use in schools, hospitals, food processing plants. |
| Limitations |
Will not cure when temperature is below
50°F. Do not apply when rain is expected. Most high gloss
enamels become slippery when wet. To ensure maximum safety on horizontal
surfaces, a small amount of sand or pumice may be added to give coating
nonskid characteristics. Not for immersion service nor severe chemical
environments.
|
| Surface Preparation |
Surface must be clean, dry and free of dirt, oil, grease, old loose paint, and other foreign matter. Glossy areas should be dulled by sanding. Bare wood and other rough surfaces should be sanded smooth. Painted surfaces, hand or power tool clean (SSPC-SP-2 or SSPC-SP-3), and spot prime. New cured or unpainted concrete - acid etch, rinse thoroughly with clean water, and allow to dry before applying coating.
|
| Application |
MIXING:The mix ratio is 4 parts Component "A" to 1 part Component "B" Activator. Agitate each component separately, then slowly mix Component "B" in container of Component "A", and mix thoroughly for 5 minutes. Wait 30 minutes for induction time. APPLICATION: Apply by Brush, Roller, or Spray. Roll: 3/8" - 1/2" synthetic roller cover. Keep roller wet. Roll in one direction, rewet then cross roll. Do not over-roll. This can result in micro-bubbles, especially in warm weather. Airless Spray settings @ 77º: May be force dried at up to 140ºF. Dries
to touch in 6 hours. May be put into service after 12 hours. Recoatable
in 16 - 24 hours. |
| Clean Up |
Clean up immediately after use with soap
& water. |
| Disposal |
Dispose of properly.
|
|
Caution |
Technical Information |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
HARMFUL OR FATAL IF SWALLOWED. SKIN AND EYE IRRITANT. VAPOR HARMFUL. MAY AFFECT THE BRAIN OR NERVOUS SYSTEM CAUSING DIZZINESS, HEADACHE OR NAUSEA. CAUSES EYE, NOSE AND THROAT IRRITATION. MAY BE HARMFUL IF ABSORBED THROUGH THE SKIN. CONTAINS GLYCOL ETHER. NOTICE: Reports have associated repeated and prolonged occupational overexposure to solvents with permanent brain and central nervous system damage. Intentional misuse by deliberately concentrating and inhaling contents may be harmful or fatal. Use with adequate ventilation. To avoid breathing vapors or spray mist, open windows and doors or use other means to ensure fresh air entry during application an drying. If you experience eye watering, headache or dizziness or if air monitoring demonstrates vapor/mist levels are above applicable limits, wear an appropriate properly fitted respirator (see Code of Federal Regulations 42 CFR 84) during and after application. Follow respirator manufacturer's directions for respirator use. Close container after each use. Do not get in eyes, on skin or on clothing. Wash thoroughly after handling. WARNING: This product contains a chemical known to the state of California to cause cancer and birth defects or other reproductive harm. FIRST AID: In case of contact with eyes, flush immediately with plenty of water for at least 15 minutes. Get medical attention immediately. If you experience difficulty in breathing, leave the area to obtain fresh air. If continued difficulty is experienced, get medical assistance immediately. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. If swallowed, do not induce vomiting. Call physician immediately. In case of medical emergency, contact 1-800-424-9300.
USE WITH ADEQUATE VENTILATION. ATTENTION: The container is hazardous when empty. Empty container retains explosive vapors and flammable residues. All labeled hazard precautions must be observed. Keep away from heat, sparks, and flames. Do not cut, puncture or weld on or near the container. Not rated for pressure, do not apply air or gas pressure. Do not reuse the container for any purpose. Obtain And Read The Material Safety Data Sheet Before Using. INTENDED FOR INDUSTRIAL USE ONLY. Manufactured For: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||